ABPM
Product Detailed
Related Categories:General Assay & Diagnostic Apparatus
ABPM
1.Noninvasive oscillometric ABP monitor
2.Up to 24th Automatic ABP monitoring
3.PDA System
4.Small,portable and good-s
ABPM
ECHO-60 Ambulatory Blood Pressure Monitor
Noninvasive oscillometric ABP monitorUp to 24th Automatic ABP monitoringSmall,portable and good-shapedPowerful functions and ease of operationManual activationResults directly shown on LCD of ABP monitorMicroprocessor controlled for reliability and accuracySoftware features
Windows 98/2000/XP English/Chinese PlatformWindows Mobile System(PDA)XP style inferface,ease of operation,clear of view,and freely English-Chinese language switchingCreate new patient files,and manage the databaseDownload data from ABP recorderQuick and reliable replayFive different graph types and a table report including notes,easy to convert patient files to any formats for further analysis and editingTechnical Specifications
Method of measurement | Oscillometer with step deflation |
Display | LCD display Sys., Dia., HR and Time |
test range of systolic blood pressure | 70 mmHg-290 mmHg |
test range of diastole blood pressure | 40 mmHg-150 mmHg |
Accuracy | ±5 mmHg |
pulse frequency | 40beat/min-200beat /min |
test duration | ≥24 hours |
Release pressure protection | Put out the battery during the measurement, cuff can release pressure and protect patient safety |
Data protection | put out the battery or change battery during the 24 hours measurement, data does not lost and save automatically. |
Test memory | Up to 400 times completely measurements |
Power | DC 3V(+5%,-10%),2AA 5# alkali battery |
Battery capacity | with one set of batteries between 140-180 times measurement may be carried out |
Input Power | when pumping, electric current should be less than 300mA |
Dimensions | 110mm×80mm×35mm |
Weight | Approx. 255g(including batteries) |
operation environment temperature range | 5°C - 40°C |
relative humidity | ≤80% |
air pressure | 700hPa -1060hPa |
Storage condition temperature range | -20°C - +50°C |
relative humidity | 15% -95% |
air pressure | 500hPa - 1060hPa |
Data connector | USB cable |
System security classification | internal power B type |
ABPM